1.
Heliyon ; 9(7): e18271, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37539099

RESUMO

Natural ventilation in low-budget elementary schools is the main focus to ensure the health and comfort of its occupants, specifically when looking at the global pandemic related to SARS-COV-2. This paper presents an experimental and novel study of natural ventilation in a public elementary school (Los Zumacales), with a particularly low economic budget. The study was carried out during the winter months of the Covid 19 pandemic. The school is located in the rural area of Castilla y León (North-Western Spain) far from high traffic roads. In this study, a methodology of measuring CO2 concentration was applied in nine classrooms in a school. The experimental study shows the level of natural ventilation in each classroom, expressed in Air Changes per Hour (ACH), using the Decay CO2 concentration method. The method is proven by comparing the experimental values of the obtained ACH with those determined by the most powerful methods to achieve appropriate ventilation levels. Thus, ensuring health protection protocol in rural schools, against the COVID 19 pandemic. Harvard guide and Spanish regulations (RITE), two widely recognized methods have been used together with the experimentally obtained standard by Rey et al. Only one classroom showed a value lower than 3 indicating poor ventilation. In this study, the degree of thermal comfort in the nine classrooms were also analyzed according to the EN15251 standard. An average indoor temperature of approximately 19 °C was obtained, and the relative humidity was stable and correct according to Spanish regulations. In addition, the risk of infection in each classroom was estimated following the international method recommended by the federation of European Heating, Ventilation, and Air Conditioning Associations (REHVA). The probability of infection in all the cases studied was less than 14%. Therefore, this study provides a strong response against infections illnesses, such as Covid 19, in educational buildings where economic budgets of their facilities are low in both, maintenance and investment.

2.
Build Environ ; 185: 107265, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32939104

RESUMO

In this research paper, an analysis is developed on the performance of a hybrid ventilation system that combines Earth-to-Air Heat eXchangers (EAHX), free cooling and evaporative cooling Air Handling Unit Heat eXchanger (AHU-HX), all being controlled by a Building Management System (BMS) in a net Zero Energy Building (nZEB), called LUCIA. LUCIA nZEB is the first safe-building against Covid-19 in the world, certified by the international organisation WOSHIE, and located in Valladolid, Spain. The main aim is to optimize the performance of the three systems in such a way that the Indoor Air Quality (IAQ) levels remain within the allowable limits, while maximizing the use of natural resources and minimizing energy consumption and carbon emissions. The approach to satisfy the heating and cooling demand and IAQ levels through zero emissions energy systems is developed, thus anticipating the zero-energy target, set by the European Union for 2050. Results showed that the installed hybrid ventilation system uses heat exchangers for 70% of the operational time, in order to achieve the set parameters successfully. Also, the analysis made by monitoring data, have shown that the control and optimal operation of the hybrid ventilation system allows high energy recovery values with minimum additional electricity consumption. Significant reduction of carbon emissions and operational costs have been achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...